ARD LOGIC BOARD
ICS - ARD 2
Product Specification ICS – ARD 2
Duty Combination DOL, V3F
Max. Motor capacity 7.5 kw
Door Operator Manual Door or Auto Door.
Normal Power Supply 380 volt/400volt/415 volt AC, 3 Phase, 4 wire
Input Frequency 50 Hz.
Inverter Output Voltage 48 volt AC, 3 Phase.
Battery Charger SMPS Based Boost Cum Float charger.
Nominal Battery voltage 48 volt D.C., 12 x 4, 7 Ah.
Type of Battery Sealed Maintenance Free.
Battery life 2 years.
Maximum Backup Time 2.5 Minutes.
Inverter Efficiency > 85%
Cooling System Natural Air cooling.
Speed during Rescue Run 4 -6 Hz.
Maximum Rescue Runs per day 8 nos.
Rescue Operation Performs Rescue Operation while Total Power failure or single Phasing.
Working Operation Battery to ARD Transformer to ARD Logic Board to Motor & Break via safety circuit